GloMax® Navigator Microplate Luminometer
Easy-to-Use, Luminescence Plate Reader
- Plate-reading luminometer for convenient detection of bioluminescence
- Developed and optimized with Promega cell and gene reporter assays
- Over 40 preloaded assay protocols
Catalog Number:
Choose an option
Catalog Number: GM2000
Catalog Number: GM2010
Sensitive, Ready-to-Use Microplate Luminometer
GloMax® Navigator is an easy-to-use microplate luminometer integrated with Promega chemistries for superior luminescence assay performance. The instrument comes ready to use—simply unpack it, plug it in and begin your experiments. You can also interpret results using integrated data analysis software.
GloMax® Navigator provides superior sensitivity and dynamic range for both strong and weak bioluminescence experimental samples as well as seamless integration with Promega bioluminescence assays, including gene reporter, cell-based and biochemical assays. The microplate luminometer features optional dual injectors to measure both glow- and flash-based luminescent reactions in 96-well plates.
The luminometer is operated by an integrated Tablet PC, which provides quick and easy navigation through the control options. Exporting your results is simple with a variety of options, including export to your local data network, USB flash drive and cloud-based storage location.
Preloaded Protocols for Faster, Easier Data Analysis
GloMax® Instruments Come with Dozens of Preloaded Protocols
Easy 24-Hour Kinetic Reads for Live-Cell Assays
Easy Multi-Day Reads for Real-Time Assays
GloMax® Application Notes
No need to reinvent the wheel—we’ve already used GloMax® instruments for everything from cell viability, toxicity and metabolism, kinase and cell signaling, reporter gene assays, nucleic acid quantitation for NGS sequencing, PROTACs and protein degradation, bioassays, BRET, ELISAs and even water quality testing. Search our Application Notes collection for examples using GloMax® instruments with a wide range of bioluminescence- and fluorescence-based assays.
Luminometer Performance
- Simple touch screen navigation with full PC capabilities.
- Choose from over 30 preloaded protocols and spend less time optimizing.
- Build custom protocols using the intuitive drag-and-drop interface.
- Export data to a network, cloud or any drive desired.
- Highest instrument sensitivity to measure the lowest assay signals.
- Low cross-talk between wells gives you better, more usable results.
- Broad dynamic range of the instrument extends the linear range of your assay.
- Designed to comply with FDA 21CFR Part 11 regulations
- Provides user authentication and authorization, data integrity and protection, electronic signatures, and audit trails
- IQ/OQ service available
- Field-based service available
Accurate Results from Every Well
There are three ways that microplate readers can affect how much useful information you get from each plate. Poor sensitivity may cause you to miss low-level samples that could be the “hit” you are looking for. Letting the signal from bright wells spill into adjacent wells allows crosstalk to occur and skews your experimental results. And a narrow detection range limits the accuracy and reproducibility that your work requires. With the GloMax® plate readers, you can rest easy and have confidence in your results.GloMax® microplate readers offer superior sensitivity and auto-gain adjustment letting you measure weak and strong signals on the same plate.
The masking design of GloMax® microplate readers means you can be confident that the results from each well are not skewed by signal from neighboring wells.
With the broad detection range of GloMax® microplate readers, you can measure signals ranging from high intensity to near physiological levels.
Microplate Reader Compliance for Your GxP Workflow
Not sure if GloMax® Navigator is the right choice for your lab?
Find the instrument that's right for your needs. Compare Plate Readers
Service and Support
One Call Supports It All
Promega supplies both the reagents and the instrument, so one call to Promega answers any questions you may have about assay chemistries or instrument performance.
Ensure Minimal Instrument Downtime
- Field Support and Loaner Programs
- Service Packages
- IQ and OQ Packages
Warranty and Service Agreements
- Backed by a one-year warranty.
- Additional warranty and service agreements are available.
- For more information contact Promega Technical Services
Design Features
| Detection Modes | Luminescence |
| Sample Format | 96-well plates |
| Tablet PC | Windows® 8.1 or 10 Tablet PC with USB connection to instrument |
| Dimensions |
18.6in (47.2cm) width 20.0in (50.8cm) depth 9.4in (23.9cm) height without Tablet and PC mounted 18in (45.7cm) height with Tablet and PC mounted |
| Weight | Approximately 40lbs. (18.1kg) |
| Power Requirements | 120VA, 50/60 HZ |
| Warranty | 1-year parts and labor warranty included |
| Regulatory Compliance | For Research Use Only. Not for use in Diagnostic Procedures |
| Detector | Top-reading, head-on photon counting photomultiplier tube (PMT) |
| Wavelength Range | 350–700nm |
| Detection Limit | 1.5 × 10-21 moles of luciferase |
| Linear Dynamic Range | >9 logs |
| Cross-talk | Less than 3 × 10-5 (white, 96-well plate, Corning 3912) |
| Number of injectors (optional) | Two injectors |
| Dispense Volume Range | 5–200µl in 1µl increments |
| Plate Compatibility | 96-well plates |
| Injection Speed | 20–500µl per second |
| Waste Collection Tray Volume | Approximately 50ml |
| Void Volume | 500µl |
| Operating System | Windows® 8.1 or 10 Professional version, 64-bit, with USB connection to instrument |
| RAM | 4GB |
| Disk Space | 64GB |
| Other Requirements | Microsoft.NET 4.6.1 Framework or newer (full version) |
Available Separately
| Product | Catalog # |
|---|---|
| Dual Injector Pump Station Upgrade for GloMax® Navigator | SA1304 |
| Replacement Tubing Set, GloMax® Navigator | GM2030 |
| Light Plate | E6531 |
| USB Ethernet Adapter | AS8403 |
| Bar Code Reader | AS3200 |
| GloMax® Navigator Sales Rental | E5302 |
| GloMax® Navigator Installation Qualification | SA1305 |
| GloMax® Navigator Operational Qualification | SA1306 |
| GloMax® Navigator Installation and Operational Qualification | SA1307 |
| GloMax® Navigator Preventive Maintenance | SA1308 |
| GloMax® Navigator Standard Service Agreement | SA1301 |
| GloMax® Navigator Premier Service Agreement | SA1313 |
| GloMax® Navigator Premier Warranty Upgrade | SA1312 |
Specifications
Catalog Number:
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
See Protocol for storage recommendations.
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
See Protocol for storage recommendations.
Resources
Related Products
Similar Products
Frequently Used With
QC Test Plate for GloMax® Instruments
The ideal solution for organizations that demand consistent and efficient validation of GloMax® microplate readers.
GM9000
GloMax® Navigator System Services and Accessories
For use with the GloMax® Navigator System.
E5302, SA1304, SA3040, SA3041, SA3042, SA3050, SA3051, SA3052, SA1305, SA1306, SA1307, SA1301, SA1308, E6531, GM2030, AS8403, AS3200, SA1313, SA1312
96-Well Sterile Microplates
Recommended for luminescence detection of ATP using the Water-Glo™ System.
E5650
Nano-Glo® Dual-Luciferase Reporter Assay System
Ultra-sensitive detection of firefly and NanoLuc® luciferase activities in a single sample.
N1610, N1620, N1630, N1650, N1521, N1531, N1541, N1551
Caspase-Glo® 3/7 Assay System
An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity.
G8090, G8091, G8093, G8092
Bio-Glo™ Luciferase Assay System
Bioluminescent detection reagent qualified for use with bioassays that utilize firefly luciferase.
G7940, G7941
BacTiter-Glo™ Microbial Cell Viability Assay
Measure the number of viable microbial cells in culture with a luminescent signal proportional to the amount of ATP present.
G8230, G8231, G8232, G8233
Luminometer Injector Tubing Cleaning Kit
70% Ethanol Solution and ATP-Free Water to use with Water-Glo™ 96 Kits for GloMax® Instrument injector cleaning.
AM1110